inet
WDS
Upatikanaji: | |
---|---|
Wingi: | |
Faida ya bidhaa
1. Mbio za urefu - hadi maili 90
Kasi ya 2.
Hadi 1Mbps (inet900)
3.Secure - Tabaka nyingi za usalama wa cyber pamoja na:
AES-128 Encryptio
Uthibitishaji wa radius
4.Ethernet na miingiliano ya serial inaruhusu uhamiaji wa vifaa vya serial vilivyopo kwenye mitandao ya IP
5. Utendaji wa Daraja la Mchanganyiko - UL Darasa la 1 Div 21 & Kiwango cha joto kilichopanuliwa kwa mazingira yaliyokithiri
6.License Bure - Tuma mara moja
7.pluy na unganisho la kucheza - Usanidi hauhitaji karibu hakuna usanidi
Uwezo wa 8.VLAN (802.1q) inaruhusu data nyingi zilizogawanywa juu ya redio moja
9.Long Range Wireless Ethernet
10.Gateway ya mitandao ya serial/urithi na/au vifaa kwa mtandao wa IP
11.Video na/au sauti-juu-ip
Upataji wa mtandao wa 12Mobile kwa operesheni ya msingi wa gari n
Faida ya bidhaa
1. Mbio za urefu - hadi maili 90
Kasi ya 2.
Hadi 1Mbps (inet900)
3.Secure - Tabaka nyingi za usalama wa cyber pamoja na:
AES-128 Encryptio
Uthibitishaji wa radius
4.Ethernet na miingiliano ya serial inaruhusu uhamiaji wa vifaa vya serial vilivyopo kwenye mitandao ya IP
5. Utendaji wa Daraja la Mchanganyiko - UL Darasa la 1 Div 21 & Kiwango cha joto kilichopanuliwa kwa mazingira yaliyokithiri
6.License Bure - Tuma mara moja
7.pluy na unganisho la kucheza - Usanidi hauhitaji karibu hakuna usanidi
Uwezo wa 8.VLAN (802.1q) inaruhusu data nyingi zilizogawanywa juu ya redio moja
9.Long Range Wireless Ethernet
10.Gateway ya mitandao ya serial/urithi na/au vifaa kwa mtandao wa IP
11.Video na/au sauti-juu-ip
Upataji wa mtandao wa 12Mobile kwa operesheni ya msingi wa gari n
Vigezo vya kiufundi
Mkuu | ||||
Kiwango cha data: | 256kbps/512kbps (inet300) 512kbps/1Mbps (INET900) Kiungo cha hewa kinachoweza kusanidiwa 1,200-115.2 BPS bandari za serial | |||
Bendi ya mara kwa mara: | 336-344 MHz ISM Band (INET300) 902-928 MHz ISM Band (INET900) | |||
Njia ya kueneza: | DTS/FHSS | |||
Anuwai (inet300-256kbps): | Aina ya kawaida ya kudumu: maili 25 Upeo wa kiwango cha juu: 90miles Aina ya kawaida ya rununu (iliyohifadhiwa): 8miles Aina ya kawaida ya rununu (kusonga): 5miles | |||
Anuwai (inet300-512kbps): | Aina ya kawaida ya kudumu: maili 15 Upeo wa masafa ya kudumu: 25miles | |||
Anuwai (inet900-512kbps): | Aina ya kawaida ya kudumu: maili 25 Upeo wa kiwango cha juu: 90miles Aina ya kawaida ya rununu (iliyohifadhiwa): 8miles Aina ya kawaida ya rununu (kusonga): 5miles | |||
Anuwai (inet900-1Mbps): | Aina ya kawaida ya kudumu: maili 15 Upeo wa masafa ya kudumu: 25miles | |||
Usanidi unaopatikana: | Ufikiaji wa Upataji/Gateway mbili za mbali - Serial na Ethernet | |||
Daraja la Ethernet la mbali - Ethernet tu | Gateway ya serial ya mbali - serial tu P21 kituo kilicholindwa - redio za tow kwenye chasi moja (baridi Stangby) | |||
Redio | ||||
inet 300 | ||||
Faida ya mfumo: | 150db @ 256 kbps 140db @ 512 kbps | |||
Nguvu ya Carier: | 0.5 hadi 5 /5 hadi 25 watt | |||
Kuingiza pato: | 50 ohms | |||
Bandwidth iliyochukuliwa: | 316.5kHz | |||
Moduli: | CPFSK (Awamu inayoendelea FSK) | |||
Mpokeaji | -101dbm @ 256 kbps na 10-6 ber -97dbm @ 512 kbps na 10-6 ber | |||
inet900 | ||||
Faida ya mfumo: | 139db @ 512 kbps 134db @ 1Mbps | |||
Nguvu ya Carier: | 0.1 hadi 1 /1 hadi 15 watt | |||
Kuingiza pato: | 50 ohms | |||
Bandwidth iliyochukuliwa: | 600 kHz | |||
Moduli: | CPFSK (Awamu inayoendelea FSK) | |||
Usikivu wa mpokeaji: | -97dbm @ 512 kbps na 10-6 ber -92dbm @1Mbps na 10-6 BER | |||
Maingiliano ya mwili | ||||
Ethernet: | 10baset, RJ-45 | |||
Serial: | COM1: RS-232/485/V.24, DB-9F, DCE COM2: RS-232/485/V.24, DB-9M, DCE | |||
Anternna: | Kiunganishi cha TNC (kike) | |||
LEDs: | LAN, COM1, COM2, Nguvu, Kiunga | |||
Itifaki | ||||
Wireless: | CSMA/CA (Kuepuka mgongano) | |||
Ethernet: | IEEE 802.3. Ethernet II, spanning Mti (kufunga), IGMP | |||
TCP/IP: | DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP, TFTP | |||
Serial: | PPP, encapsulation juu ya IP (tunneling) ya itifaki za async multidrop pamoja na modbus.dnp.3.df1, BSAP | |||
Hiari: | Allen- Bradley Ethernet/IP* - MODBUS/TCP | |||
Suite ya usalama wa cyber, kiwango cha 4 | ||||
Usimbuaji: | AES-128 na mzunguko wa ufunguo wa moja kwa moja | |||
Uthibitishaji: | 802.1x, radius, EAP/TLS. PKI, PAP, Chap | |||
Usimamizi: | SSL, SSH, Hyps | |||
Utenganisho wa Trafiki: | 802.1q Vlan | |||
Usimamizi | ||||
HTTP, HTTPS, SSH, Telnet, Console ya ndani | ||||
SNMPV1/V2/V3, MIB II, Enterprise MIB | ||||
Syslog | ||||
NetView MSTM | ||||
Mazingira | ||||
TEMBESS: | -40 ℃ hadi +70 ℃ (-40 ° F hadi +158 ° F) | |||
Unyevu: | 95% kwa 40 ℃ (104 ° F) isiyo ya kufurika | |||
Umeme | ||||
inet 300 | ||||
Voltage ya pembejeo: | 10.5-16VDC | |||
Matumizi ya sasa (nominella): | Modi Kusambaza Pokea | 13.8VDC 1.2a (5W RF pato) 5.0A (25W RF Pato) 203m | ||
inet 900 | ||||
Voltage ya pembejeo: | 10.5-30VDC (1W), 10.5-16VDC (15W) | |||
Matumizi ya sasa (nominella): | Modi Kusambaza Pokea | 13.8VDC 510mA 5.0a (15W RF Pato) 200mA | 24VDC 290mA (1W) 120mA | |
Mitambo | ||||
Kesi die cast alumini | ||||
Vipimo: | inet 300 3.8h x 20.3W x 10.2d cm (5W) 5.0h x 20.3W x 10.2d cm (25W) inet 900 3.15h x 17.2W x 11.2d cm (1W) 5.0h x 20.3W x 10.2d cm (15W) | |||
Uzito: | Inet 300: 1kg (5W), 1.2kg (25W) Inet 900: 908g (1W), 1.2kg (15W) | |||
Chaguzi za kuweka.FLAT Mlima wa uso | Brackets.Din Rail, 19 'Rack Tray | |||
Chaguo la P21: | Kesi ya chuma (rack inayoweza kuwekwa 2U) Vipimo: 8.9h x 48.3W x 35.6d cm (3.5h x 19w x 14d in) Uzito: 7.6kg, (14.7lbs) na transceivers | |||
Idhini ya wakala | ||||
Sehemu ya FCC 15.247 | ||||
UL/CSA Darasa la 1 Div.21 | ||||
Ic |
Vigezo vya kiufundi
Mkuu | ||||
Kiwango cha data: | 256kbps/512kbps (inet300) 512kbps/1Mbps (INET900) Kiungo cha hewa kinachoweza kusanidiwa 1,200-115.2 BPS bandari za serial | |||
Bendi ya mara kwa mara: | 336-344 MHz ISM Band (INET300) 902-928 MHz ISM Band (INET900) | |||
Njia ya kueneza: | DTS/FHSS | |||
Anuwai (inet300-256kbps): | Aina ya kawaida ya kudumu: maili 25 Upeo wa kiwango cha juu: 90miles Aina ya kawaida ya rununu (iliyohifadhiwa): 8miles Aina ya kawaida ya rununu (kusonga): 5miles | |||
Anuwai (inet300-512kbps): | Aina ya kawaida ya kudumu: maili 15 Upeo wa masafa ya kudumu: 25miles | |||
Anuwai (inet900-512kbps): | Aina ya kawaida ya kudumu: maili 25 Upeo wa kiwango cha juu: 90miles Aina ya kawaida ya rununu (iliyohifadhiwa): 8miles Aina ya kawaida ya rununu (kusonga): 5miles | |||
Anuwai (inet900-1Mbps): | Aina ya kawaida ya kudumu: maili 15 Upeo wa masafa ya kudumu: 25miles | |||
Usanidi unaopatikana: | Ufikiaji wa Upataji/Gateway mbili za mbali - Serial na Ethernet | |||
Daraja la Ethernet la mbali - Ethernet tu | Gateway ya serial ya mbali - serial tu P21 kituo kilicholindwa - redio za tow kwenye chasi moja (baridi Stangby) | |||
Redio | ||||
inet 300 | ||||
Faida ya mfumo: | 150db @ 256 kbps 140db @ 512 kbps | |||
Nguvu ya Carier: | 0.5 hadi 5 /5 hadi 25 watt | |||
Kuingiza pato: | 50 ohms | |||
Bandwidth iliyochukuliwa: | 316.5kHz | |||
Moduli: | CPFSK (Awamu inayoendelea FSK) | |||
Mpokeaji | -101dbm @ 256 kbps na 10-6 ber -97dbm @ 512 kbps na 10-6 ber | |||
inet900 | ||||
Faida ya mfumo: | 139db @ 512 kbps 134db @ 1Mbps | |||
Nguvu ya Carier: | 0.1 hadi 1 /1 hadi 15 watt | |||
Kuingiza pato: | 50 ohms | |||
Bandwidth iliyochukuliwa: | 600 kHz | |||
Moduli: | CPFSK (Awamu inayoendelea FSK) | |||
Usikivu wa mpokeaji: | -97dbm @ 512 kbps na 10-6 ber -92dbm @1Mbps na 10-6 BER | |||
Maingiliano ya mwili | ||||
Ethernet: | 10baset, RJ-45 | |||
Serial: | COM1: RS-232/485/V.24, DB-9F, DCE COM2: RS-232/485/V.24, DB-9M, DCE | |||
Anternna: | Kiunganishi cha TNC (kike) | |||
LEDs: | LAN, COM1, COM2, Nguvu, Kiunga | |||
Itifaki | ||||
Wireless: | CSMA/CA (Kuepuka mgongano) | |||
Ethernet: | IEEE 802.3. Ethernet II, spanning Mti (kufunga), IGMP | |||
TCP/IP: | DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP, TFTP | |||
Serial: | PPP, encapsulation juu ya IP (tunneling) ya itifaki za async multidrop pamoja na modbus.dnp.3.df1, BSAP | |||
Hiari: | Allen- Bradley Ethernet/IP* - MODBUS/TCP | |||
Suite ya usalama wa cyber, kiwango cha 4 | ||||
Usimbuaji: | AES-128 na mzunguko wa ufunguo wa moja kwa moja | |||
Uthibitishaji: | 802.1x, radius, EAP/TLS. PKI, PAP, Chap | |||
Usimamizi: | SSL, SSH, Hyps | |||
Utenganisho wa Trafiki: | 802.1q Vlan | |||
Usimamizi | ||||
HTTP, HTTPS, SSH, Telnet, Console ya ndani | ||||
SNMPV1/V2/V3, MIB II, Enterprise MIB | ||||
Syslog | ||||
NetView MSTM | ||||
Mazingira | ||||
TEMBESS: | -40 ℃ hadi +70 ℃ (-40 ° F hadi +158 ° F) | |||
Unyevu: | 95% kwa 40 ℃ (104 ° F) isiyo ya kufurika | |||
Umeme | ||||
inet 300 | ||||
Voltage ya pembejeo: | 10.5-16VDC | |||
Matumizi ya sasa (nominella): | Modi Kusambaza Pokea | 13.8VDC 1.2a (5W RF pato) 5.0A (25W RF Pato) 203m | ||
inet 900 | ||||
Voltage ya pembejeo: | 10.5-30VDC (1W), 10.5-16VDC (15W) | |||
Matumizi ya sasa (nominella): | Modi Kusambaza Pokea | 13.8VDC 510mA 5.0a (15W RF Pato) 200mA | 24VDC 290mA (1W) 120mA | |
Mitambo | ||||
Kesi die cast alumini | ||||
Vipimo: | inet 300 3.8h x 20.3W x 10.2d cm (5W) 5.0h x 20.3W x 10.2d cm (25W) inet 900 3.15h x 17.2W x 11.2d cm (1W) 5.0h x 20.3W x 10.2d cm (15W) | |||
Uzito: | Inet 300: 1kg (5W), 1.2kg (25W) Inet 900: 908g (1W), 1.2kg (15W) | |||
Chaguzi za kuweka.FLAT Mlima wa uso | Brackets.Din Rail, 19 'Rack Tray | |||
Chaguo la P21: | Kesi ya chuma (rack inayoweza kuwekwa 2U) Vipimo: 8.9h x 48.3W x 35.6d cm (3.5h x 19w x 14d in) Uzito: 7.6kg, (14.7lbs) na transceivers | |||
Idhini ya wakala | ||||
Sehemu ya FCC 15.247 | ||||
UL/CSA Darasa la 1 Div.21 | ||||
Ic |